Alloy Navigator defines a set of timeouts, intervals, and one size limit. The object attachment size limit and the online help address can be set in both the Admin Center and the Settings App, except under a Cloud license, where neither application lets you change them.

Operational limits

The table lists each limit with its default value.

Limit Default Changeable
Automation Server SQL command timeout 600 seconds No
Automation Server connection timeout 30 seconds No
Reconnect interval after a failed connection 60 seconds for 5 attempts, then 600 seconds for 5 attempts, then 3,600 seconds; 10 seconds when only the database version is wrong No
Hung-job termination A job whose log file has not changed for 60 minutes is killed Yes, in minutes
Hung-job check 10 minutes, first after connecting and then between checks No
PowerShell script timeout (does not apply to External Command scripts) 600 seconds Yes, in seconds
Log purge Once per calendar day No
Object attachment size 50 MB when no value has been saved Yes, in MB
Web App grid incremental refresh 10 seconds Yes, in seconds
Web App full refresh 60 minutes Yes, in minutes
Web App dashboard auto-refresh 5 minutes Yes, in minutes
Archive move batch 10 rows per batch No
Backup, restore, archiving, and history-clear statements No command timeout No

Each changeable value is a single system-wide setting, not a per-technician preference. The object attachment size is set on the System Performance page of the Admin Center and of the Settings App; see Attachment size limit.

For workflow logging and log retention, see Logs.

Attachment size limit

The attachment size limit is a pair of settings: a switch that turns the limit on or off, and the maximum size in megabytes. It is one value for the whole installation. If neither setting has ever been saved, the limit is on at 50 MB. In a new Alloy Navigator 2026.1 database created with the Default Workflow, the limit is set to on at 25 MB; see Default Workflow Configuration. A database upgraded from an earlier version need not have this value, and an administrator may have changed it.

In the Web App, the limit is the maximum size of each file uploaded as an attachment; when the limit is turned off, the setting no longer caps a file.

Attachment files are stored in the Alloy Navigator database, so every uploaded file adds to the size of the database.

TIP: Keep the attachment size limit turned on. Without it, large files can make the database grow and reduce system performance.

The Admin Center and the Settings App read and write the same pair, so the stored value can come from either application.

In the Admin Center

  1. Open the System Performance page.
  2. In the Attachments section, turn the attachment size limit on or off, and set the maximum size in megabytes.
  3. Save the page.

Under a Cloud license, the Admin Center does not show the Attachments section of the System Performance page; see Administering Alloy Navigator Cloud.

In the Settings App

Before you begin:

  • Your account holds the administrative right for the System Performance page. Without it, the page does not appear in the navigation tree.

To set the attachment size limit:

  1. In the navigation tree, under General, open System Performance.
  2. In the Attachments group, select Limit attachment size to to turn the limit on, or clear it to turn the limit off.
  3. With the check box selected, enter the size in the box next to it, in MB. The box is available only while the check box is selected, and its lowest value is 1.
  4. Click Save, or press Ctrl+S.

When you clear the check box and save, the limit is removed and the stored size is kept; it applies again when you select the check box and save.

When you export settings with Export Selected Settings, the System Performance node includes the two attachment settings.

Under a Cloud license, the Attachments group is shown read-only: the Limit attachment size to check box and the stored size are visible, but they cannot be changed; see Administering Alloy Navigator Cloud.

Unavailable workflow actions

In the Web App, a step action that is unavailable because of its status or additional criteria can be hidden or shown dimmed. The choice applies system-wide; the default is to hide these actions. Actions that the user's roles do not allow are always hidden. Create actions that do not meet their criteria are also hidden, and the Mobile App always hides unavailable actions regardless of this setting.

In the Settings App

  1. Open General > System Performance.
  2. In Workflow action bar, select Dim out unavailable Actions or Hide unavailable Actions.
  3. Click Apply.

The Web App reads the setting when a session connects to the server. Sessions that are already open may not show the change immediately. For what technicians see and how to run actions, see Perform Actions on Records.

Online help address

The online help address is the base address of the product's help links. It is stored in the database, and if it has never been changed, the default https://docs.alloysoftware.com is used. The Admin Center and the Settings App write the same stored address.

A help link is this address followed by the product name, the product's major version, and the help path of the program that opens it. When help is opened from an error message, the link also carries the text of the message. Three errors open a help topic of their own instead: a database provider that is not found, a workflow validation error, and a Windows logon type that is not granted during a network or remote-scan operation.

After they connect to the database, the Settings App, the Import Wizard, and the Automation Server Manager build their help links from this address. The Database Management wizard and the Database Backup/Restore wizard always link to https://docs.alloysoftware.com, and the Web Configuration tool uses a fixed link of its own, so changing the address does not affect their help links. The Active Directory Import tool and the Scheduled Task Agent have no help links.

In the Admin Center

  1. Open the Docs page.
  2. Enter the help address.
  3. Save the page.

Under a Cloud license, the help address setting on the Docs page is disabled; see Administering Alloy Navigator Cloud.

In the Settings App

Before you begin:

  • Your account holds the administrative right Help and Documentation. Without it, the page does not appear in the navigation tree.

To set the online help address:

  1. In the navigation tree, under General, open Help and Documentation.
  2. In the Online help group, enter the address in the Help URL box. To put the default address back in the box, click Set Default.
  3. Optionally, click Open in Browser to open the help at the address you typed.
  4. Click Save, or press Ctrl+S.

When the page opens, the box shows the address the Settings App read when it started. Set Default only fills the box, and Open in Browser uses the typed address, not the stored one; nothing is stored until you save. When you save, the Settings App uses the new address for its own help at once. If you close the window or move to another node while the page has unsaved changes, the Settings App asks first: Yes applies the changes, No discards them.

The Help and Documentation page is not included when you export settings with Export Selected Settings.

Under a Cloud license, the Help and Documentation page is still shown, but the Help URL box and both buttons, Open in Browser and Set Default, are disabled; see Administering Alloy Navigator Cloud.